- Contact Person : Ms. Yang Jenny
- Company Name : Pingxiang Nanxiang Chemical Packing Co., Ltd.
- Tel : 86-799-6779208
- Fax : 86-799-7096638
- Address : Jiangxi,Pingxiang,West Section, Hi-Tech Industrial Park, Pingxiang city.
- Country/Region : China
- Zip : 337000
Molecular Sieve
Typical Chemical Formula0.45 K2O . 0.55 Na2O . Al2O3 . 2 SiO2 . 4.5H2OSiO2 : Al2O3 ≈2
Technical Parameter
Item | Unit | Technical data | |||
Shape | Pellet | Sphere | |||
Diameter | mm | 1.5-1.7 | 3.0-3.3 | 1.7-2.5 | 3.0-5.0 |
Size ratio up to grade | % | ≥98 | ≥98 | ≥96 | ≥96 |
Bulk density | g/ml | ≥0.68 | ≥0.68 | ≥0.68 | ≥0.68 |
Wear ratio | % | ≤0.20 | ≤0.25 | ≤0.10 | ≤0.10 |
Crushing strength | N | ≥45/cm | ≥60/cm | ≥30/piece | ≥70/piece |
Static water adsorption | % | ≥20 | ≥20 | ≥20 | ≥20 |
Ethylene adsorption | % | ≤3.0 | ≤3.0 | ≤3.0 | ≤3.0 |
Water content, as shipped | % | ≤1.5 | ≤1.5 | ≤1.5 | ≤1.5 |
ypical Application1) Drying of unsaturated hydrocarbons (e.g. ethylene, propylene, butadien) 2) Cracked Gas Drying3) Drying of natural gas, if COS minimization is essential, or a minimum co-adsorption of hydrocarbons is required. 4) Drying of highly polar compounds, such as methanol and ethanol5) Drying of liquid alcohol6) Static, (non-regenerative) dehydration of insulating glass units, whether air filled or gas-filled.7) Drying of refrigerants
RegenerationNANXIANG molecular sieve Type 3A can be regenerated by either heating in the case of thermal swing processes; or by lowering the pressure in the case of pressure swing processes. To remove moisture from a 3A molecular sieve, a temperature of 200-230°C is required. A properly regenerated molecular sieve can give moisture dew points below -100°C.The outlet concentrations on a pressure swing process will depend on the gas present, and on the conditions of the process.
Size 3A - Zeolites are available in beads of 1-2 mm, (10x18 mesh) 2-3 mm, (8x12 mesh) , 2.5-5 mm, (4x8 mesh) and as powder, and in pellet 1.6, 3.2.
Molecular Sieve